Consultant holding a sound meter on stage in an empty auditorium beside a colleague.

Architectural acoustics · Calder Wharf

Hear the room before it is finished.

We measure offices, classrooms, lecture rooms and small halls before finishes are specified. Independent acoustic data, delivered in 10 working days, to inform your architectural specifications.

Book a room survey

  • 08:30Walk the room
  • 09:30Reverberation & noise
  • 12:00Speech & insulation
  • 15:00Findings on site
  • +10 daysReport
Empty auditorium viewed from the rear balcony with timber walls and dark seats.

Auditorium

Tiered, 420 seats · RT target 1.0–1.2 s

Measurement microphone on a tripod in the middle of an empty classroom at dusk.

Classroom

30 desks · RT target 0.6–0.8 s

Small recital hall with timber wall panels and a closed grand piano on stage.

Small hall

200 seats · RT target 1.4–1.8 s

Empty open office after hours with suspended ceiling baffles and rows of desks.

Open office

90 desks · speech privacy by zone

Four kinds of room, measured the same way: empty, in daylight or after hours, with the drawings open.

Measure
before
you specify

Interior finishes decide how a room sounds long after construction is over. Wall linings, ceiling rafts, floor build-ups and glazing set how reverberation decays and how clearly speech carries. When absorption is chosen from catalogue estimates alone, flutter echoes, excess reverberance and intrusive plant noise often call for disruptive remedial work.

We measure the bare room before finish schedules are fixed. With baseline reverberation, insulation through partitions and background noise on record, architects and contractors can still adjust materials and panel positions while drawings and procurement contracts remain open to change.

Hand holding a sound level meter with a dodecahedron loudspeaker blurred in the background.

What a survey measures

01

Reverberation time

We place an omnidirectional loudspeaker and precision microphones across the space to record decay in each octave band. Measuring the bare room shows how much absorption its volume needs before finishes are specified.

Typical target: 0.6–0.8 s in a classroom

02

Background noise from plant and street

We measure ambient sound levels by frequency band with the ventilation running, by day and in the evening. This separates plant rumble and traffic ingress from the room itself before interior work begins.

Typical target: NR 25–30 in quiet lecture spaces

03

Sound insulation between rooms

With a high-output test signal we measure airborne and impact transmission across shared walls and floor slabs. Finding flanking paths early shows whether the partition specification gives the privacy the rooms need.

Typical target: DnT,w ≥ 48 dB between teaching rooms

04

Speech clarity at the back row

We evaluate early-to-late sound ratios and speech transmission from the speaker position to the rear rows. It confirms whether listeners can follow spoken words without strain or a wash of reflections.

Typical target: STI ≥ 0.60 for lecture rooms

Report

Four parts, ten working days

Every report gives clear data and practical guidance to adjust finishes before procurement.

Dim ceiling of a small hall showing suspended timber reflectors and upper seating rows.

An empty room tells you what it will do to every voice that fills it.

Small hall, after hours

Recent surveys

3 case notes

Consultant standing with a sound meter at the lectern of a tiered lecture room.

A 180-seat lecture room that echoed

Room typeTiered lecture room

Volume1,450 m³

MeasuredRT 1.9 s (mid-frequency)

Target0.7–0.9 s for speech

Year2026

Person carrying a tripod across an open office floor with suspended ceiling rafts.

Ninety desks, one quiet corner

Room typeOpen-office floor

Volume1,100 m², 90 desks

MeasuredNoise and speech privacy by zone

TargetQuieter team zones

Year2026

Side balcony view of an empty recital hall with a softly lit timber stage.

A small hall for chamber music

Room typeRecital hall, 240 seats

Volume2,900 m³

MeasuredRT 1.4 s

Target1.6–1.8 s for chamber music

Year2026

Fees

Fixed before we travel

ItemFee (EUR, VAT excluded)
Small-room survey — one room up to 300 m³ (classroom, meeting room)€680
Room survey — one room 300–2,000 m³ (lecture room, open-office floor, rehearsal room)€1,180
Hall survey — one room 2,000–8,000 m³ (auditorium or small hall up to 600 seats)€2,400
Additional room, same building, same visit€420 per room
Sound insulation test between two rooms (one wall or floor)€360 per partition
Finish-schedule review meeting, 2 hours (on site or video)€290

Every survey includes the visit, the written report delivered in 10 working days and one 30-minute call about the report. Travel within 80 km of Calder Wharf is included; beyond that, €0.60 per km return. Fees per visit, in euros, VAT excluded.

How booking works

Step 1

Send drawings and room hours. Floor plans, room volumes and the hours the empty room is available.

Step 2

Fixed fee and date confirmed within 2 working days. We check scope and travel distance, then confirm the fee in writing.

Step 3

Survey visit, one day, the room empty. Measurements run in quiet daytime hours or in an evening session.

Step 4

Report in 10 working days. Decay curves, noise levels and finish proposals in one written report.

Step 5

Optional finish-schedule review. A two-hour session, on site or by video, to go through the proposed materials.