A 180-seat lecture room that echoed

Room type

Tiered lecture room

Volume

1,450 m³

Measured

RT 1.9 s (mid-frequency)

Target

0.7–0.9 s for speech

Consultant

Leila Farouk

Year

2026

In early 2026, Otonoha Acoustics was invited to survey a newly enclosed 180-seat tiered lecture hall measuring approximately 1,450 m³. The structural shell was fully weather-tight, featuring fair-faced painted concrete flank walls, raked concrete floor risers, and an exposed structural ceiling slab. Although the room was intended for university lectures and spoken presentations, initial acoustic impressions indicated substantial flutter echo and ringing resonance across the seating rake, making normal conversation difficult to understand past the third row of seats.

Consultant Leila Farouk conducted the on-site survey starting at 08:30 on a scheduled weekday visit. Using calibrated omnidirectional dodecahedron loudspeakers and precision sound level microphones placed across eight discrete receiver positions, our team recorded impulse responses, speech transmission index values, and baseline background noise. The measured mid-frequency reverberation time averaged 1.9 seconds, with noticeable energy lingering around 500 Hz and 1,000 Hz. For an academic lecture space of 1,450 m³ reliant on unamplified or lightly amplified speech, the recognized target range is 0.7 to 0.9 seconds. The bare room exceeded this benchmark by more than a full second.

Analysis of the raw decay curves revealed that sound energy was reflecting repeatedly between the unyielding parallel side walls and bouncing back into the rear seating rows from the high rear wall. In addition, the hard concrete soffit reflected vocal energy downwards with delayed arrival times, smearing spoken consonant clarity. Background ambient noise from the building air supply measured within normal limits, confirming that reverberation was the dominant source of acoustic degradation. Because the project team had engaged our studio before finishes were specified, the room’s interior surface contracts remained open, presenting an ideal window for targeted architectural acoustic interventions without the cost of demolition or retrofit modifications.

The final acoustic report, delivered within our standard ten working days, proposed a coordinated distribution of sound absorption rather than uniform wall cladding. Specifically, the report proposed installing high-performance absorptive fabric-wrapped panels across the upper half of the rear wall to eliminate delayed slap-back reflections to the front lectern. For the ceiling, the report recommended suspended horizontal acoustic baffles arranged above the seating rake, leaving the central ceiling area reflective to preserve natural acoustic projection from the lecturer towards the rear tiers.

Furthermore, the report proposed selective treatment on the side walls, incorporating slatted timber panels backed with mineral insulation along the rear third of each flank. This approach was designed to control lateral flutter echoes while maintaining visual warmth in keeping with the architect’s aesthetic intent. Consistent with our independent consultancy practice, Otonoha Acoustics recommended generic material specifications without endorsing proprietary manufacturer products. A follow-up thirty-minute consultation call with the architectural design team reviewed the calculated absorption areas, ensuring that proposed finish materials matched the project’s mechanical ventilation paths and lighting layouts prior to contractor tender.