A wide plant room with two chillers, insulated pipework and one technician small in the far background.

Contracts · twelve months, sixty days’ notice

Maintenance Contracts

A maintenance year

Quarterly visits fall in March, June, September and November.

Our maintenance agreements provide structured preventative care for commercial heating, ventilation, and cooling systems across Rotterdam and surrounding areas. Each contract runs for twelve months with sixty days notice and establishes regular visits, predictable maintenance costs, and a permanent building service log.

Visits

Quarterly or monthly, month by month

A technician slides a clean pleated filter into an open commercial air-handling unit.

A quarterly contract distributes maintenance across four scheduled visits each year in March, June, September, and November. The March visit prepares cooling systems for warmer weather, verifying compressor staging, testing safety switches, and inspecting electrical connections. June brings mid-season checks focusing on condenser cleanliness, filter condition, and condensate drainage during peak cooling demands. In September, technicians evaluate late-summer component wear and clean heat exchange surfaces.

March

Cooling start-up: compressor staging, safety switches, electrical connections.

June

Mid-season: condenser cleanliness, filters and condensate drainage.

September

Late-summer wear, heat exchange surfaces cleaned.

November

Heating changeover: controls tuned and dampers set for winter.

4 visits a year · €2,400 from

A technician and a facilities manager at an open controls cabinet, pointing at relays and a thermostat module.

For intensive commercial facilities, healthcare practices, and high-occupancy office buildings, our monthly maintenance tier provides twelve scheduled attendances per year. This tier includes every task performed in our quarterly schedule, supplemented by rigorous monthly monitoring. Technicians log differential filter pressures each month to identify restricted airflow before fan motors strain. We inspect and clear condensate trays and drainage lines monthly to prevent ceiling leaks during humid weather.

January

Monthly reading: filter pressure, controls, drain check.

February

Monthly reading: filter pressure, controls, drain check.

March

Cooling start-up, plus the monthly readings.

April

Monthly reading: filter pressure, controls, drain check.

May

Monthly reading: filter pressure, controls, drain check.

June

Mid-season coil and drain clean, plus readings.

July

Monthly reading: filter pressure, controls, drain check.

August

Monthly reading: filter pressure, controls, drain check.

September

Heat exchange surfaces cleaned, plus readings.

October

Monthly reading: filter pressure, controls, drain check.

November

Heating changeover, plus the monthly readings.

December

Monthly reading: filter pressure, controls, drain check.

12 visits a year · €8,400 from

What each visit covers

The November visit executes the annual heating changeover, tuning burner or heat-pump controls and securing dampers against winter drafts. During each visit, our technicians replace air filters, lubricate bearings, test fan belts, clear drain trays, and conduct F-gas certified refrigerant inspections. Annual quarterly coverage starts at 2,400 euros for buildings with up to four units.

Monthly visits also include detailed controls readings, sensor calibration checks, and thermostat adjustments to prevent drift in critical zones. Monthly clients receive priority dispatch with a target response time of four hours during weekday operational hours. Monthly maintenance agreements start at 8,400 euros per year for systems encompassing up to twelve units.

What is excluded from the annual maintenance contract?

Our contract fees cover all scheduled labor, travel, preventative diagnostics, routine lubrication, filter inspections, and seasonal adjustments. Consumable replacement parts, including drive belts, contactors, and fresh filter media, are supplied at direct cost and itemised on the service report before installation.

Major capital replacements, such as full compressor replacements or complete air-handling unit retrofits, fall outside regular maintenance and are quoted separately with clear engineering estimates. Every contract client receives a dedicated service record consisting of one physical binder left on site in the plant room and one shared digital PDF updated after each visit.

This log remains with the building, providing a permanent historical record of operating pressures, component replacements, and regulatory inspections.

Request a survey hour

One hour on your roof and in your plant room with Leila Haddad, a written report within 3 working days. €190, credited to your first contract year.

+31 10 555 0140 · Mon–Fri 07:30–17:30